{"product_id":"risscheck-rissprufmittel","title":"Set of 3 RISS-CHECK Penetrant Testing Agents","description":"\u003ch2 data-start=\"3103\" data-end=\"3157\"\u003eRISS-CHECK Application – 3-Part Crack Detection Set\u003c\/h2\u003e\n\u003cp data-start=\"3159\" data-end=\"3401\"\u003eThe \u003cstrong data-start=\"3163\" data-end=\"3204\"\u003eRISS-CHECK penetrant testing 3-part set\u003c\/strong\u003e is a proven system for \u003cstrong data-start=\"3228\" data-end=\"3286\"\u003enon-destructive testing using the dye penetrant method\u003c\/strong\u003e in accordance with \u003cstrong data-start=\"3306\" data-end=\"3327\"\u003eDIN EN ISO 3452-2\u003c\/strong\u003e.\u003cbr data-start=\"3328\" data-end=\"3331\"\u003eThe system is designed to reliably detect \u003cstrong data-start=\"3373\" data-end=\"3400\"\u003esurface-breaking cracks\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-start=\"3403\" data-end=\"3446\"\u003eComponents of the RISS-CHECK 3-Part Set\u003c\/h3\u003e\n\u003cul data-start=\"3448\" data-end=\"3687\"\u003e\n\u003cli data-start=\"3448\" data-end=\"3524\"\u003e\n\u003cp data-start=\"3450\" data-end=\"3524\"\u003e\u003cstrong data-start=\"3450\" data-end=\"3478\"\u003eRISS-CHECK Penetrant Red\u003c\/strong\u003e\u003cbr data-start=\"3478\" data-end=\"3481\"\u003epenetrates even the finest surface cracks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3525\" data-end=\"3610\"\u003e\n\u003cp data-start=\"3527\" data-end=\"3610\"\u003e\u003cstrong data-start=\"3527\" data-end=\"3557\"\u003eRISS-CHECK Cleaner-Remover\u003c\/strong\u003e\u003cbr data-start=\"3557\" data-end=\"3560\"\u003efor pre-cleaning and removal of excess penetrant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3611\" data-end=\"3687\"\u003e\n\u003cp data-start=\"3613\" data-end=\"3687\"\u003e\u003cstrong data-start=\"3613\" data-end=\"3643\"\u003eRISS-CHECK Developer White\u003c\/strong\u003e\u003cbr data-start=\"3643\" data-end=\"3646\"\u003emakes penetrated cracks clearly visible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3694\" data-end=\"3743\"\u003eTesting Procedure (Dye Penetrant Method)\u003c\/h2\u003e\n\u003cp data-start=\"3745\" data-end=\"3820\"\u003eThe crack inspection using the RISS-CHECK system is carried out as follows:\u003c\/p\u003e\n\u003col data-start=\"3822\" data-end=\"4330\"\u003e\n\u003cli data-start=\"3822\" data-end=\"3929\"\u003e\n\u003cp data-start=\"3825\" data-end=\"3929\"\u003e\u003cstrong data-start=\"3825\" data-end=\"3852\"\u003eCleaning and degreasing\u003c\/strong\u003e\u003cbr data-start=\"3852\" data-end=\"3855\"\u003eThoroughly clean the test surface using the RISS-CHECK Cleaner-Remover.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3931\" data-end=\"4098\"\u003e\n\u003cp data-start=\"3934\" data-end=\"4098\"\u003e\u003cstrong data-start=\"3934\" data-end=\"3953\"\u003eApply penetrant\u003c\/strong\u003e\u003cbr data-start=\"3953\" data-end=\"3956\"\u003eSpray RISS-CHECK Penetrant Red evenly onto the surface.\u003cbr data-start=\"4014\" data-end=\"4017\"\u003ePenetration time: \u003cstrong data-start=\"4038\" data-end=\"4057\"\u003e3 to 25 minutes\u003c\/strong\u003e, depending on material and defect depth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4100\" data-end=\"4207\"\u003e\n\u003cp data-start=\"4103\" data-end=\"4207\"\u003e\u003cstrong data-start=\"4103\" data-end=\"4130\"\u003eRemove excess penetrant\u003c\/strong\u003e\u003cbr data-start=\"4130\" data-end=\"4133\"\u003eRemove penetrant residue from the surface using the RISS-CHECK Cleaner.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4209\" data-end=\"4330\"\u003e\n\u003cp data-start=\"4212\" data-end=\"4330\"\u003e\u003cstrong data-start=\"4212\" data-end=\"4231\"\u003eApply developer\u003c\/strong\u003e\u003cbr data-start=\"4231\" data-end=\"4234\"\u003eShake RISS-CHECK Developer well and spray evenly.\u003cbr data-start=\"4286\" data-end=\"4289\"\u003eDevelopment time: \u003cstrong data-start=\"4310\" data-end=\"4329\"\u003e1 to 25 minutes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"4332\" data-end=\"4427\"\u003eDuring development, cracks appear as \u003cstrong data-start=\"4369\" data-end=\"4426\"\u003eclearly visible red indications on a white background\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"4434\" data-end=\"4457\"\u003eAreas of Application\u003c\/h2\u003e\n\u003cp data-start=\"4459\" data-end=\"4571\"\u003eRISS-CHECK crack detection is used wherever \u003cstrong data-start=\"4503\" data-end=\"4559\"\u003esurface-breaking defects must be reliably identified\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul data-start=\"4573\" data-end=\"4768\"\u003e\n\u003cli data-start=\"4573\" data-end=\"4589\"\u003e\n\u003cp data-start=\"4575\" data-end=\"4589\"\u003e\u003cstrong data-start=\"4575\" data-end=\"4589\"\u003eWeld seams\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4590\" data-end=\"4606\"\u003e\n\u003cp data-start=\"4592\" data-end=\"4606\"\u003e\u003cstrong data-start=\"4592\" data-end=\"4606\"\u003eCast parts\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4607\" data-end=\"4645\"\u003e\n\u003cp data-start=\"4609\" data-end=\"4645\"\u003e\u003cstrong data-start=\"4609\" data-end=\"4645\"\u003eMechanical and plant engineering\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4646\" data-end=\"4671\"\u003e\n\u003cp data-start=\"4648\" data-end=\"4671\"\u003e\u003cstrong data-start=\"4648\" data-end=\"4671\"\u003eAutomotive industry\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4672\" data-end=\"4690\"\u003e\n\u003cp data-start=\"4674\" data-end=\"4690\"\u003e\u003cstrong data-start=\"4674\" data-end=\"4690\"\u003eShipbuilding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4691\" data-end=\"4718\"\u003e\n\u003cp data-start=\"4693\" data-end=\"4718\"\u003e\u003cstrong data-start=\"4693\" data-end=\"4718\"\u003eAircraft construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4719\" data-end=\"4768\"\u003e\n\u003cp data-start=\"4721\" data-end=\"4768\"\u003e\u003cstrong data-start=\"4721\" data-end=\"4768\"\u003ePressure vessels and apparatus construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4770\" data-end=\"4851\"\u003eThe method is primarily used on \u003cstrong data-start=\"4802\" data-end=\"4824\"\u003emetallic materials\u003c\/strong\u003e, but is also suitable for:\u003c\/p\u003e\n\u003cul data-start=\"4853\" data-end=\"4895\"\u003e\n\u003cli data-start=\"4853\" data-end=\"4865\"\u003e\n\u003cp data-start=\"4855\" data-end=\"4865\"\u003ePlastics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4866\" data-end=\"4887\"\u003e\n\u003cp data-start=\"4868\" data-end=\"4887\"\u003eCeramic materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4888\" data-end=\"4895\"\u003e\n\u003cp data-start=\"4890\" data-end=\"4895\"\u003eGlass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"4902\" data-end=\"4943\"\u003eAdvantages of RISS-CHECK Testing\u003c\/h2\u003e\n\u003cul data-start=\"4945\" data-end=\"5113\"\u003e\n\u003cli data-start=\"4945\" data-end=\"4977\"\u003e\n\u003cp data-start=\"4947\" data-end=\"4977\"\u003eNon-destructive testing method\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4978\" data-end=\"5015\"\u003e\n\u003cp data-start=\"4980\" data-end=\"5015\"\u003eHigh sensitivity for surface cracks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5016\" data-end=\"5034\"\u003e\n\u003cp data-start=\"5018\" data-end=\"5034\"\u003eEasy application\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5035\" data-end=\"5074\"\u003e\n\u003cp data-start=\"5037\" data-end=\"5074\"\u003eComplies with international standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5075\" data-end=\"5113\"\u003e\n\u003cp data-start=\"5077\" data-end=\"5113\"\u003eIdeal for safety-critical components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5115\" data-end=\"5316\"\u003e\u003cstrong data-start=\"5115\" data-end=\"5124\"\u003eNote:\u003c\/strong\u003e\u003cbr data-start=\"5124\" data-end=\"5127\"\u003eDefects must be \u003cstrong data-start=\"5143\" data-end=\"5166\"\u003eopen to the surface\u003c\/strong\u003e for this method to be effective. Surface cracks are among the most critical defects, as stress concentration can lead to premature component failure.\u003c\/p\u003e\n\u003cp data-start=\"5323\" data-end=\"5342\"\u003e\u003cstrong data-start=\"5323\" data-end=\"5342\"\u003eMade in Germany\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"1763\" data-end=\"1825\"\u003eFrequently Asked Questions about RISS-CHECK Detection\u003c\/h2\u003e\n\u003cp data-start=\"1827\" data-end=\"2011\"\u003e\u003cstrong data-start=\"1827\" data-end=\"1874\"\u003eWhich standard does RISS-CHECK comply with?\u003c\/strong\u003e\u003cbr data-start=\"1874\" data-end=\"1877\"\u003eThe RISS-CHECK system is suitable for non-destructive testing using the dye penetrant method in accordance with \u003cstrong data-start=\"1989\" data-end=\"2010\"\u003eDIN EN ISO 3452-2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2013\" data-end=\"2200\"\u003e\u003cstrong data-start=\"2013\" data-end=\"2063\"\u003eWhich defects can be detected with RISS-CHECK?\u003c\/strong\u003e\u003cbr data-start=\"2063\" data-end=\"2066\"\u003eThe method detects \u003cstrong data-start=\"2085\" data-end=\"2131\"\u003esurface-breaking cracks, pores and defects\u003c\/strong\u003e that are open to the surface. Subsurface defects cannot be detected.\u003c\/p\u003e\n\u003cp data-start=\"2202\" data-end=\"2423\"\u003e\u003cstrong data-start=\"2202\" data-end=\"2252\"\u003eWhich materials can be tested with RISS-CHECK?\u003c\/strong\u003e\u003cbr data-start=\"2252\" data-end=\"2255\"\u003eThe method is mainly used on \u003cstrong data-start=\"2284\" data-end=\"2306\"\u003emetallic materials\u003c\/strong\u003e, but can also be applied to \u003cstrong data-start=\"2335\" data-end=\"2367\"\u003eplastics, ceramics and glass\u003c\/strong\u003e, provided the surface is suitable and defects are open.\u003c\/p\u003e\n\u003cp data-start=\"2425\" data-end=\"2589\"\u003e\u003cstrong data-start=\"2425\" data-end=\"2473\"\u003eIs the crack testing method non-destructive?\u003c\/strong\u003e\u003cbr data-start=\"2473\" data-end=\"2476\"\u003eYes, RISS-CHECK is a \u003cstrong data-start=\"2497\" data-end=\"2531\"\u003enon-destructive testing method\u003c\/strong\u003e. The component remains fully functional after inspection.\u003c\/p\u003e\n\u003cp data-start=\"2591\" data-end=\"2759\"\u003e\u003cstrong data-start=\"2591\" data-end=\"2630\"\u003eIs cleaning required after testing?\u003c\/strong\u003e\u003cbr data-start=\"2630\" data-end=\"2633\"\u003eYes, after completing the inspection, the component should be cleaned to remove any remaining penetrant or developer residues.\u003c\/p\u003e","brand":"RVK Store","offers":[{"title":"Default Title","offer_id":50293309440285,"sku":null,"price":32.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0945\/3640\/1181\/files\/risscheck123.jpg?v=1756280183","url":"https:\/\/shop.rvklier.com\/products\/risscheck-rissprufmittel","provider":"RVK Store","version":"1.0","type":"link"}